Hi
We are using the Shutdown.bat file. After this, when we use run.bat, we get the following error:
java.lang.NoSuchMethodException: No such accessible
method: addActionConfig() on object: org.apache.struts.config.ApplicationConfig
Apparently there is no complete shutdown. We have to wait for half an hour odd before using run.bat again, for successful deployment.
After doing a shutdown, we do observe that certain ports are still open, in the "TIME_WAIT" state. These apparently pertain to JBoss.
Any pointers? What do i need to do to ensure complete shutdown? Do we have any relevant script for the same?
Thank you.
Try 3.0.1+, a halt was added after the shutdown processing
to close stubborn sockets stuck in OS code.
Regards,