This content has been marked as final.
Show 1 reply
-
1. Re: How to use more information than entries lifespan to control their expiration
rvansa Nov 24, 2014 5:45 AM (in response to abrahamdia)1 of 1 people found this helpfulYou must not use expiration until the entry really can expire. You should probably store the reference counter directly inside the entry (or maybe in the metadata?) and update this using listeners on the other entries. As you don't want to send whole value over network when updating just the reference number part, you can implement DeltaAware interface.