Issue with JMS in clustering servers
manmayeesenapati Apr 18, 2016 10:27 AMRecently we have upgraded our application from Jboss 6.1 to 6.4. But we are getting JMS exception while starting the server.
10:00:10,526 INFO [stdout] (ServerService Thread Pool -- 111) PCEServer.JMSMonitor: JMS-StartupCheck disabled.
10:00:11,157 INFO [stdout] (sib.Logger) [LOG] 2016-04-18, 10:00:11.140 AM EDT [Server:Alpha.Trx.node02] [WsId:0] [Session:null]
10:00:11,158 INFO [stdout] (sib.Logger) Thread[Thread-5,5,main]
10:00:11,158 INFO [stdout] (sib.Logger) Class : (StartupLogger)
10:00:11,158 INFO [stdout] (sib.Logger) Revision :
10:00:11,158 INFO [stdout] (sib.Logger) ErrorNo : 520135
10:00:11,158 INFO [stdout] (sib.Logger) ErrorCode : 2
10:00:11,158 INFO [stdout] (sib.Logger) ExtErrorCode : 2
10:00:11,158 INFO [stdout] (sib.Logger) Level : Error
10:00:11,158 INFO [stdout] (sib.Logger) AddInfo : Exception occured while receiving(JMS) and dispatching event!
10:00:11,158 INFO [stdout] (sib.Logger) Description : RuntimeException occurred
10:00:11,158 INFO [stdout] (sib.Logger) javax.jms.JMSException: com.myproclassic.server.events.PCEAbstractEvent; local class incompatible: stream classdesc serialVersionUID = 1734262104002485498, local class serialVersionUID = 7073076377269056890
10:00:11,158 INFO [stdout] (sib.Logger) at java.io.ObjectStreamClass.initNonProxy(ObjectStreamClass.java:616)
10:00:11,158 INFO [stdout] (sib.Logger) at java.io.ObjectInputStream.readNonProxyDesc(ObjectInputStream.java:1623)
10:00:11,158 INFO [stdout] (sib.Logger) at java.io.ObjectInputStream.readClassDesc(ObjectInputStream.java:1518)
10:00:11,158 INFO [stdout] (sib.Logger) at java.io.ObjectInputStream.readNonProxyDesc(ObjectInputStream.java:1623)
10:00:11,158 INFO [stdout] (sib.Logger) at java.io.ObjectInputStream.readClassDesc(ObjectInputStream.java:1518)
10:00:11,158 INFO [stdout] (sib.Logger) at java.io.ObjectInputStream.readNonProxyDesc(ObjectInputStream.java:1623)
10:00:11,158 INFO [stdout] (sib.Logger) at java.io.ObjectInputStream.readClassDesc(ObjectInputStream.java:1518)
10:00:11,158 INFO [stdout] (sib.Logger) at java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:1774)
10:00:11,158 INFO [stdout] (sib.Logger) at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1351)
10:00:11,158 INFO [stdout] (sib.Logger) at java.io.ObjectInputStream.readObject(ObjectInputStream.java:371)
10:00:11,158 INFO [stdout] (sib.Logger) at org.hornetq.jms.client.HornetQObjectMessage.getObject(HornetQObjectMessage.java:159)
10:00:11,158 INFO [stdout] (sib.Logger) at com.myproclassic.server.services.jmsevents.beans.PCEJmsReceiverBean.onMessage(PCEJmsReceiverBean.java:56)
10:00:11,158 INFO [stdout] (sib.Logger) at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
10:00:11,158 INFO [stdout] (sib.Logger) at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:62)
10:00:11,158 INFO [stdout] (sib.Logger) at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43)
10:00:11,158 INFO [stdout] (sib.Logger) at java.lang.reflect.Method.invoke(Method.java:498)
I have checked my application ear there is no duplicate class for PCEAbstractEvent, for which its telling serial version ID issue is showing . Attached my jboss ha XML for your reference