1. Re: Two entries in PROCESSINSTANCELOG per each process
swiderski.maciej Mar 12, 2015 2:29 AM (in response to vinniman)what data base are you running this on?
What is extremely weird is that the identity column is empty and that should not happen when it was invoked from workbench. Do you use custom application to interact with engine and then view it in workbench? If so make sure you don't have any duplicates of event listeners that might impact that.
HTH
-
2. Re: Two entries in PROCESSINSTANCELOG per each process
vinniman Mar 12, 2015 4:54 AM (in response to swiderski.maciej)Oracle, and yes, I use custom app to start processes and console to observe.
Commented out JPAWorkingMemoryDbLogger in event listeners in kie-deployment-descriptor of my kjar and it helped.
Thank you!
But earlier (in version 6.1.0.Final) i had to explicitly define this logging listener to activate the logging into a DB.
Is this not a case anymore for 6.2.0.Final? So I ended up with two loggers: implicit one and one defined by me?
-
3. Re: Two entries in PROCESSINSTANCELOG per each process
swiderski.maciej Mar 16, 2015 2:34 AM (in response to vinniman)yes, whenever you use default builder for runtime manager it will register audit logger automatically.
HTH